Fault analysis and troubleshooting methods:


Q1. The die setting switch hits the horizontal position to lock the oil circuit.

-->Put the knife mold high setting switch to the straight direction


Q2, motor steering error

-->Change the two phase pairs of the motor


Q3, the working switch is in poor contact with the wire head falling off

-->Check the line to connect the line


Q4, the solenoid valve coil burned

-->replace the coil or the entire solenoid valve


Q5, the solenoid valve spool is stuck

-->cleaning the spool


Q6, stroke adjustment handle loose

-->reset the die